deploy-check β the go/no-go preflight for a lane-3 deploy
The deploy of the native Home was blocked twice, and both times the blocker was only discovered by hand after a wasted round trip: the TV was not on the network, the bundle path was the wrong module, the pinned hash had moved. the handoff carries the numbered recipe, but nothing answered the one question that matters before touching a TV:
Is this deploy safe to run right now, and if not, exactly what is wrong?
This command answers it. It runs the checks from the handoff's recipe in one shot β profile, pinned stock, build, pairing, reachability, root, and the TV's live state β before native-install.cjs is allowed near anything.
node tools/launcher-host/deploy-check.cjs --model 50a51huv --host <tv-ip> [--variant alvidaa] [--json]
node tools/launcher-host/deploy-check.cjs --model 50a51huv --fixture <dir>
Flags: --port (default 2222) and --key (default
server/keys/tv_root_ed25519) are honoured and flow into the suggested next
command.
The one rule
The checks are claims about the TV. The tool only observes; it never writes
to the TV. No writes, no restarts, no kill, no "fixing" what it finds β a
preflight that can change the thing it is checking is not a preflight. Every
remedy it prints names a command owned by somebody else:
native-install.cjs bootstrap/install for the lane, the switch script for
owner/mode, the operator for the network.
This is also why two tempting checks were dropped rather than softened:
- "clear space if /var/local is tight" β a write; the space check only reports, and its remedy lists what an operator may clear by hand.
- "flip
watcher.enabledoff when it is on" β a write to the bridge config;native-install.cjsowns that flip during install, so the preflight only warns loudly.
Exit codes
| Code | Meaning |
|---|---|
0 |
go β no FAIL; WARNs are footguns, not blockers |
1 |
no-go β at least one FAIL |
2 |
bad usage β unknown model/variant, missing --host without --fixture, bad flag |
Output
One line per check: status, short name, the observed value, and β on anything but PASS β a one-line remedy. The last line is the exact next command to run, or the reason there is not one.
PASS reachability 192.168.0.175:2222 answers
FAIL root ssh answers but not as root: uid=1000(nobody) ... | remedy: lane 3 needs root; ...
blocked by root: ssh answers but not as root: uid=1000(nobody) ...
--json prints the same result as one JSON object β and nothing else on
stdout β for a future bridge page:
{
"tool": "deploy-check", "go": false, "exit": 1,
"model": "50a51huv", "variant": "alvidaa", "host": "192.0.2.10", "port": 2222,
"checks": [ { "name": "reachability", "status": "FAIL", "observed": "β¦", "remedy": "β¦" } ],
"next": null,
"blocked": "blocked by reachability: TV not reachable: β¦"
}
The exit code and the JSON exit come from one verdict() on the same
results array, so the two modes cannot disagree.
The checks, in order
Cheap and local first, remote last, so a broken toolchain never costs a round trip.
| # | Name | Question | Outcomes |
|---|---|---|---|
| 1 | profile |
Does the model id resolve? Prints model, engine, bundle path from models.json. | always PASS (unknown model is a usage error, exit 2) |
| 2 | stock-bundle |
Does local_stock exist in the repo? |
FAIL β bootstrap remedy. Gitignored and private: absence is normal on a fresh clone. |
| 3 | stock-hashes |
Do its md5 and sha256 match the pinned stock_md5 / stock_sha256? |
FAIL on mismatch β a moved bundle must be re-pinned, never built against. |
| 4 | build |
Does the variant's builder (variants.json) build against the pinned stock into a temp file? Prints byte size + sha256. Also proves the builder refuses a deliberately wrong expected hash β that guard is the only thing stopping a build against the wrong revision. | FAIL if the build throws or the guard is gone. Temp output deleted. |
| 5 | pairing |
Is the variant listed as verified on this model? | WARN if not β say clearly that it needs --force; the suggested next command carries it. |
| 6 | reachability |
Does TCP connect to the TV's SSH port? (The firmware drops ICMP; TCP is the documented probe.) | Hard gate. FAIL names deep standby / other network; no later check is attempted. |
| 7 | root |
Does id over SSH contain uid=0? |
Hard gate. FAIL otherwise β lane 3 needs root; no later check is attempted. |
| 8 | bundle-path |
Does the profile's app path exist, with the profile's owner/mode? |
FAIL if missing. WARN on owner/mode drift β the switch script sets them, so a difference means someone has been here. |
| 9 | current-bundle |
Is the live bundle's md5 the pinned stock, this candidate (variant already installed), or something else? | always reported, never FAIL. Unknown revisions are normal: install will switch, not install. |
| 10 | engine |
Is a process for the profile's engine running? (Mirrors the switch script's live_engine(): matched on the /proc/<pid>/exe link, zombies excluded.) |
WARN if not β the switch script restarts it, but a missing engine means the UI is down. |
| 11 | bridge |
Does 127.0.0.1:8770/api/debug answer from the TV's loopback, with MQTT connected? |
WARN/SKIP, never FAIL β the native Home does not need the bridge, but the watcher and tools/screenshot.sh live there. WARN (not SKIP) because on this TV curl is present and the bridge is normally up: silence is most likely a real down bridge. |
| 12 | watcher |
Is watcher.enabled true in /var/local/alvidaa/config.json? |
WARN if true β native-install.cjs owns this; a native Home with the watcher on is bounced back to the canvas page within a second. SKIP if the config is missing/unreadable. |
| 13 | space |
How much is free where the candidate lands (/var/local)? |
WARN under 5 MB. |
Checks 2β4 SKIP (with the bootstrap remedy) when there is no verified local stock: nothing is hashed or built against a bundle that is absent or has moved.
Fixture mode β testing without a TV
The TV is unreachable from CI, so every remote interaction goes through one small interface:
// { exec(cmd) -> string, readFile(path) -> Buffer, connect(port) -> bool }
sshRemote(opts)β the real TV, oversshwith the same flags native-install.cjs uses.fixtureRemote(dir)β a fake TV: a directory read as if it were the TV's root filesystem, plus marker files for the things that are not files.
The model/variant tables and repo root are injectable the same way
(main(argv, deps)), because the pinned stock bundle is gitignored and
cannot exist in a fresh clone. deploy-check.test.cjs
builds worlds from these parts.
Fixture layout (paths under the fixture dir stand in for TV paths):
| Path | Stands in for |
|---|---|
APPS/β¦/app.js |
the live launcher bundle (content drives the md5 checks; permissions drive the mode check) |
APPS/β¦/app.js.owner |
owner override, e.g. 305:305 (tests run unprivileged and cannot chown) |
var/local/alvidaa/config.json |
the bridge config the watcher check reads |
var/local/.free-kb |
free space on /var/local (default 819200) |
bridge/api-debug.json |
the body the bridge probe returns (absent = bridge down) |
proc/<pid>/exe β symlink |
a live engine process; the symlink target must end in /<engine>; a State: line containing Z in proc/<pid>/status marks a zombie |
.unreachable (marker) |
makes connect() fail β the TV is "in deep standby" |
.nonroot (marker) |
makes id report a non-root uid |
exec() emulates exactly the handful of busybox invocations the tool issues
(id, md5sum, ls -ldn, df -k, the engine scan, the bridge curl) and
throws on anything else, so drift between the tool and the fixture
contract fails the tests loudly instead of silently passing.
Worked examples
A failing run β a fresh clone (no pinned stock) and an unreachable TV. Real
output; 192.0.2.10 is a documentation address standing in for the TV:
$ node tools/launcher-host/deploy-check.cjs --model 50a51huv --host 192.0.2.10; echo "exit=$?"
PASS profile 50A51HUV / 09.01O.P0813, engine hisenseUI, bundle /APPS/channelA/operation-ui/apps/launcher/js/app.js
FAIL stock-bundle no pinned stock bundle at firmware/50a51huv/operationui/apps/launcher/js/app.js | remedy: run: node tools/launcher-host/native-install.cjs bootstrap --model 50a51huv --host 192.0.2.10
SKIP stock-hashes no local stock bundle to hash | remedy: node tools/launcher-host/native-install.cjs bootstrap --model 50a51huv --host 192.0.2.10
SKIP build no local stock bundle to hash | remedy: node tools/launcher-host/native-install.cjs bootstrap --model 50a51huv --host 192.0.2.10
PASS pairing alvidaa is verified on 50A51HUV / 09.01O.P0813
FAIL reachability TV not reachable: no TCP answer on 192.0.2.10:2222 β it may be in deep standby (all ports close, the MAC stays in ARP) or on another network | remedy: check Settings β Network β Network Information for its address
blocked by stock-bundle: no pinned stock bundle at firmware/50a51huv/operationui/apps/launcher/js/app.js (+1 more FAIL)
exit=1
A passing run β real output from a fixture shaped like the 50A51HUV deploy (the pinned stock is gitignored, so the example pins a scratch stand-in):
PASS profile 50A51HUV / 09.01O.P0813, engine hisenseUI, bundle /APPS/channelA/operation-ui/apps/launcher/js/app.js
PASS stock-bundle firmware/scratch/stock.js
PASS stock-hashes md5 e89e63a8d24e58b5a1d43db8bb4f6b9a, sha256 a0a499b459f5289c0906576e3e6ec367fcc2771dc20bdc47bfd4512cf81078d4
PASS build 224576 bytes, sha256 fca52261d2d3fb6f25278d38b3f1dc0f4b8c5a3b10354553c80873d64eeed463
PASS pairing alvidaa is verified on 50A51HUV / 09.01O.P0813
PASS reachability 192.168.0.175:2222 answers
PASS root uid=0(root) gid=0(root) groups=0(root)
PASS bundle-path /APPS/channelA/operation-ui/apps/launcher/js/app.js is 305:305 755
PASS current-bundle e89e63a8d24e58b5a1d43db8bb4f6b9a β stock
PASS engine hisenseUI running (pid 431)
PASS bridge answers, MQTT connected
PASS watcher watcher disabled
PASS space 600.0 MB free on /var/local
next: node tools/launcher-host/native-install.cjs install alvidaa --model 50a51huv --host 192.168.0.175
Go. The next command is the real one β same variant, model, host, and any
--port/--key/--force the run asked for.
Notes
- The TV's busybox is trimmed: no
wc,tail,tr,strings,readlink,sha256sum.md5sumruns on the TV (check 9); everything sha256 is computed on the host (checks 3β4). scpdoes not work on this TV; everything goes oversshβ one shortexecper remote check, no sessions left open.ls -ldngives numeric owners (the profile's305:305has no passwd entry); if the TV's busybox drops-n, the check falls back tols -ld, whose columns line up the same way.- The watcher check reads the bridge's config at
/var/local/alvidaa/config.json, which is where the launcher lane keeps it on both supported models.
Tests
node --test tools/launcher-host/deploy-check.test.cjs
Fifteen cases: the healthy TV (every check PASS), the unreachable TV, the
non-root shell, the unknown current bundle, watcher on/off, the missing and
the tampered pinned stock, the --json contract, the usage errors, and the
WARN paths (owner drift, missing engine, tight space, unverified pairing).